- FIRE AND GAS MAPPING SERVICES
- SITE SURVEY AND BOMBA INSPECTION
- PREVENTIVE & CORRECTIVE MAINTENANCE
- TRAINING
FIRE FIGHTING DIVISION
FIRE FIGHTING DIVISION
- FIRE SUPPRESSION DESIGN
- CYLINDER HYDROSTATIC TEST
- SITE INSTALLATION AND COMMISSIONING
- GAS SUPPRESSION REFILLING (FM200, CO2 AND NOVEC1230)
- SITE SURVEY AND BOMBA INSPECTION
- PREVENTIVE & CORRECTIVE MAINTENANCE
- TRAINING
PASSIVE FIRE PROTECTION DIVISION
- STRUCTURAL & ELECTRICAL PASSIVE FIRE PROTECTION SERVICES. FIREPROOFING SYSTEMS SUCH AS COATINGS, JACKETS & BLANKETS WHICH DO NOT NEED MECHANICAL ACTIVATION – TO PROTECT STRUCTURES UNDER FIRE
- OUR FIREPROOFING TECHNIQUES OFFERED INCLUDES CEMENTITIOUS SPRAY AND / OR TROWEL, CEMENT SYSTEMS, FIRE PROTECTION COATINGS, CLADDING FOR DUCTING AND FIREPROOFING TO STRUCTURES, VESSELS & PIPEWORK.
- OUR SERVICES COME WITH CERTIFIED CHARTEK & PYROCRETE APPLICATIONS. UNDER A NORMAL INSTALLATION, THE FINISHED APPLICATION RESULTS IN TWO-HOURS OF FIRE RESISTANCE
- MAINTAIN STRUCTURAL INTEGRITY OF METAL SUPPORTS BEFORE COLLAPSE. STEEL STRUCTURE COLLAPSE WITHIN 5 MINUTES IN HYDROCARBON FIRE.
- ALBI –WATER-BASE
- PITT-CHAR – SOLVENT-BASE
- PASSIVE FIRE PROTECTION MATERIALS
- CONCRETE
- CEMENTITIOUS PRODUCTS
- EPOXY INTUMESCENT COATINGS
- ACRYLIC INTUMESCENT COATINGS
- FIRE PROOFING CASTING
- FIRE PROOFING JACKETS
- TEST STANDARDS OF PASSIVE FIRE PROTECTION (CELLULOSIC)
- BS 476 PART 7-FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES
- ASTM E119-FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS
- ISO 834-FIRE-RESISTANCE TESTS-ELEMENTS OF BUILDING CONSTRUCTION
- TEST STANDARDS OF PASSIVE FIRE PROTECTION (HYDROCARHON)
- UL 1709 RAPID RISE FIRE TESTS OF PROTECTION MATERIALS FOR STRUCTURAL STEEL
- JET FIRE-SINTEF TEST (NORWAY)
- JET FIRE-BRITISH GAS TEST (SPADE ADAMS-UK)
- TESTING BODIES
- UNDERWRITER LABORATORIES (UL)-USA
- NORWEGIAN PETROLEUM DIRECTORATE (NPD)
- SINTEF (NORWAY)
- DET NORSKE VERITAS (DNV) – NORWAY
- LLOYDS REGISTER – UK
- BAM – GERMANY (VESSELS)
- EXXONMOBIL – US
- FIRE TEST HEAT FLUX
- CELLULOSIC FIRE 100KW/M²
- HYDROCARBON FIRE 200KW/M²
- JET FIRE 300KW/M²
- TEST CRITERIA
- STABILITY- THE CONSTRUCTION MUST REMAIN STABLE DURING THE PERIOD OF THE FIRE AND MUST NOT COLLAPSE.
- INTEGRITY- THE CONSTRUCTION MUST MAINTAIN ITS INTEGRITY DURING THE TEST PERIOD SUCH THAT NO GAPS OF SUFFICIENT WIDTH OPEN UP TO ALLOW PENETRATION OF FLAMES.
- INSULATION- THE FIRE INSULATION PROPERTIES OF THE CONSTRUCTION MUST BE SUCH THAT UNEXPOSED FACE MUST NOT INCREASE IN TEMPERATURE BY MORE THAN AN AVERAGE OF 140°C OR BY MORE THAN 180°C AT ANY ONE POINT FOR THE DURATION OF THE TEST I.E 2 HOURS.
- PASSIVE FIRE PROTECTION RATINGS
- STRUCTURAL INTEGRITY (LOAD BEARING) –
- “A” RATING (CELLULOSIC) = 60 MINUTES.
- “H” RATING (HYDROCARBON) = 120 MINUTES.
- NON-LOAD BEARING –
- “B” RATING FROM 15 MINUTES .
- INSULATION –
- “A0” (CELLULOSIC) = 60 MINUTES FIRE PROTECTION + NO INSULATION REQUIRED-NO LIMIT ON BACK FACE.
- “A60” (CELLULOSIC) = 60 MINUTES FIRE PROTECTION + 60 MINUTES INSULATION-BACK FACE LIMIT REQUIRED.
- “H0” (HYDROCARBON) = 120 MINUTES FIRE PROTECTION + NO INSULATION REQUIRED.
- “H60” (HYDROCARBON) = 120 MINUTES FIRE PROTECTION + 60 MINUTES INSULATION.
- “H120” (HYDROCARBON) = 120 MINUTES FIRE PROTECTION + 120 MINUTES INSULATION.
- STRUCTURAL INTEGRITY (LOAD BEARING) –